Availability: 82 in stock
  • Refund will be given as: Money back or exchange (buyer's choice)
  • Number of Pieces: 1
  • Manufacturer Part Number: allsunEM2271A
  • Item must be returned within: 30 Days
  • Resolution: 0.01mm/0.1mil
  • Returns Accepted: Returns Accepted
  • Type: Paint Thickness Gauge
  • Warranty: 1 Year
  • Condition: New
  • Return shipping will be paid by: Buyer
  • Temperature Coefficient: 0.15x(2% of reading ± 0.05mm)/°C(28°C)
  • Power Supply: 3V button cell, CR2032 or equivalent, 1 piece
  • Measuring Range: 0.00mm - 2.20mm, or 0.0mil - 86.0mil
  • Country/Region of Manufacture: China
  • Operating Environment: 0°C~40°C, Relative humidity
  • Brand: allsun
  • Set or Single Item: Single Item

    Description

    Shop Category
    Store Home
    Automotive Tester
    Digital Multimeter
    Digital Clamp Meter
    Voltage Tester
    Environment Tester
    Battery Tester
    Metal Detector
    Pen Probe Digital Multimeter
    Stud Finder
    Wood Moisture Tester
    Handheld Digital Scopemeter
    Professional Tester
    Home Meter
    Netcable Tester
    Other
    Automotive Digital Tool Car Painting Thickness Gauge Coating Tester 2.2mm/86mil
    This tester is designed to not-destructively measure the thickness of non-magnetic coatings(including paint,enamel,plastic,epoxy,etc)on iron,steel or aluminum.
    Notice:
    In order to obey the shipping security rules and passing the customs security check. We had put a insulation strip under the battery to make it insulated. You need to take the strip off and re-install the battery for the first-use.
    Specification
    Type:
    Painting Thickness Tester
    Measuring Range:
    0.00mm - 2.20mm, or 0.0mil - 86.0mil
    Measurement Accuracy:
    For measurements in “NFe” or “Fe” test mode in which the tester has been properly calibrated: ± 0.05mm
    For measurements in auto test mode and on object with aluminum substrate: ± ( 2% of reading + 0.05mm )
    For measurements in auto test mode and on object with steel substrate: ± ( 10% of reading + 0.10mm )
    Note:The above accuracy specifications assume that the operating temperature is 23º C ± 5º C and the
    operating relative humidity is ≤ 75%.
    Resolution:
    0.01mm/0.1mil
    Power Supply:
    3V button cell, CR2032 or equivalent, 1 piece
    Operating Environment:
    0°C~40°C, Relative humidity
    Temperature Coefficient:
    0.15x(2% of reading ± 0.05mm)/°C(28°C)
    Storage Environment:
    Temperature:
    -10ºC to 50ºC
    Relative Humidity:
    ≤ 80%
    Size:
    6.9*3.8*2cm
    Weight:
    About 29g(including button cell)
    Operating Instruction
    1. Hold the tester and make sure that it is as least 20cm away from the object to be tested and other objects.
    Then press the "
    TEST
    " button to turn on the tester. The display shows all segments and symbols
    momentarily. Then it shows the "
    AUTO
    "
    symbol and the measurement unit “
    mm
    ”, and meanwhile, "
    ",
    " ", and "
    " appear on the display sequentially and repeatedly.
    2. Press the "
    " button to select desired measurement unit - mm or mil.
    3. After you turn on the tester, it will default to auto test mode and the display will show
    "
    AUTO
    " as an
    indication. You can repeatedly hold down the "
    " button for about 1 sec to step through "
    NFe
    " test mode
    ( "
    NFe
    " appears as an indication ), "
    Fe
    " test mode ( "
    Fe
    " appears as an indication), and back to the auto
    test mode ( "
    AUTO
    " appears as an indication ).
    I
    f you can not obtain the naked substrate of the object to be measured and have not calibrated the tester
    using the naked substrate of this object, you must select auto test mode. The advantage of using auto test
    mode is that it is not necessary to calibrate the tester, and the disadvantage is that measurement accuracy in
    auto test mode is relatively low.
    If you have calibrated the tester using the naked substrate of this object in the "
    NFe
    " or "
    Fe
    " test mode,
    set the tester in the same test mode ( in which the tester has been calibrated by using the naked substrate of
    this object ). The advantage of using
    "
    NFe
    " or "
    Fe
    " test modes is that measurement accuracy in "
    NFe
    " or
    "
    Fe
    " test mode is high, and the disadvantage is that the tester must be calibrated in this selected test mode
    beforehand by using the naked substrate of this object.
    4. Firmly press the tester's probe perpendicularly against the surface of the object to be tested. When the tester
    detects a stable reading, this reading will be shown on the display and it is the value of the total thickness of
    the
    non-magnetic coatings on the
    substrate. This reading will be held on the display until the tester turns off
    or you make a new measurement. If necessary, you can press the “
    TEST
    ” button to erase this reading and
    then test again.
    5. If you have not operated the tester about 30 secs, it will turn off automatically. To turn off the tester manually,
    hold down the "
    TEST
    " button for more than 1 sec.
    HOW TO CALIBRATE THE TESTER
    Before you make measurement in "
    NFe
    "or "
    Fe
    " mode, you must make sure that in this mode the tester has
    been calibrated by using the naked substrate of the object to be tested or using a naked substrate which is
    completely same as the substrate of the object to be tested.
    After you finish calibrating the tester in "
    NFe
    " or "
    Fe
    " test mode, the tester will save the resulting calibration
    data in this test mode automatically. The calibration data will not be lost even when the tester turns off or when
    you replace the button cell. But whenever you calibrate the tester again in the same test mode, the already
    existing calibration data saved in this test mode will be overwritten by the new calibration data. Thus, only the
    lastest calibration data of all calibration data obtained in "
    NFe
    " mode can be retained in "
    NFe
    " mode, and
    only the lastest calibration data of all calibration data obtained in "
    Fe
    " mode can be retained in "
    Fe
    " mode.
    Item Specifics
    Brand
    all-sun
    Manufacturer Part Number
    allsunEM2271A
    Type
    Thickness Gauge
    Warranty
    Yes
    Country/Region of Manufacture
    China
    UPC
    788537553694
    Measuring Range
    0.00mm - 2.20mm, or 0.0mil - 86.0mil
    Resolution
    0.01mm/0.1mil
    Overrange Indication
    “ OL ” shown on the display
    Power Supply
    3V button cell, CR2032 or equivalent, 1 piece
    Operating Environment
    Temperature: 0ºC to 40º C
    Relative Humidity
    ≤ 80%
    Temperature Coefficient
    0.15×( 2% of reading±0.05mm)/ºC (28ºC)
    Storage Environment
    Temperature:-10ºC to 50ºC
    Size
    6.9×3.8×2cm
    Weight
    About 29g ( including button cell )
    Copyright of XXXX. All rights reserved.
    Powered by SoldEazy
    On Apr-22-19 at 01:39:25 PDT, seller added the following information: